Nubaria III Combined Cycle Power Plant (750 MW) Main Technical Parameters Minimize

STEAM GENERATOR :
 
MANUFACTURER:
STF
QUANTITY :
2
TYPE :
Horizontal, natural circulation, non-fired
MCR FLOW :
 
100% FLOW : (Guaranteed Load)
HP=76.1   -   IP=13   - LP=8.2
SUPERHEATER OUTLET (@ Guaranteed load): [oC]
HP=567.7   -   IP=326.4   - LP=300.8
REHEATER OUTLET (@ Guaranteed load): [oC]
566.5
FUEL : Type / Flow, kg/sec @ Guaranteed load
Non-fired
 
 
MAIN TURBINE
 
MANUFACTURER :
Alstom
QUANTITY :
1
TYPE :
Reaction turbine with sliding parameters
THROTTLE CONDITIONS :
HP: 565.3 C 125.06 bara   RH: 564.5C 22.0 bara
 
 
MAIN GENERATOR
 
QUANTITY :
1
RATING :
324 MVA, 0.85 (PF) lagging at CCW temp=31C
TYPE OF COOLING :
TEWAC
 
 
CONDENSER
 
QUANTITY :
1
RATING (Heat Duty, KW):
1,555 (kJ/hr x 106) = 431,944 kW
EFFECTIVE COOLING SURFACE :
18,770 m2
WATER FLOW RATE :
10.2 m3/s
COOLING WATER TEMPERATURE (In/Out):
30/40
PRESSURE (Shell):
0.026 – 0.086 bara
TUBES (Material / Size):
316 L St. Steel
 
 
FEED WATER PUMPS
 
QUANTITY :
3x50%
 
 
TYPE :
ring-section, horizontal, centrifugal
RATING (Flow / TDH):
288.5/337.8 m3/hr 1952/564 m
SUPPLIER :
TM.P
 
 
CIRCULATING WATER PUMPS
 
QUANTITY :
3x50%
TYPE :
Vertical wet pit
RATING :
5.1 m3/s
SUPPLIER :
TM.P
 
 
COMPRESSED AIR SYSTEM
 
MAIN COMPRESSOR :
2x100% instrument 2x100% service
CAPACITY :
instrument/service 245/115 scmh 
SUPPLIER :
Tender Stage
EMERGENCY COMPRESSOR :
NA
DRYERS :
 
RECEIVERS :
2/1 m3

 
 
Print