Login     Sunday, September 07, 2008
El-Tebbin Thermal Power Plant (2x350 MW) Main Technical Parameters Minimize

STEAM GENERATOR
 
MANUFACTURER:
Ansaldo Caldaie
QUANTITY :
2
TYPE :
Gas/Oil Fired boiler – Drum type
MCR FLOW :
304 kg/sec
100% FLOW :
289.58 kg/sec
SUPERHEATER OUTLET (@ Guaranteed load):
C/bar   541 / 173.12
REHEATER OUTLET (@ Guaranteed load):
C/bar   541 / 36.05
FUEL : Type / Flow, kg/sec @ Guaranteed load
N.G. / 17.44     - Mazout / 19.79
 
 
MAIN TURBINE
 
MANUFACTURER :
Alstom
QUANTITY :
2
TYPE :
3 casing cylinders reheat turbine
THROTTLE CONDITIONS :
174.8 bar / 538 C / 294.44 kg/sec
 
 
MAIN GENERATOR
 
QUANTITY :
2
RATING :
371.5 MW - PF 0.85
TYPE OF COOLING :
Hydrogen
 
 
CONDENSER
 
QUANTITY :
2
RATING (Heat Duty, KW):
396943 (w/10% tube plugged)
EFFECTIVE COOLING SURFACE :
17782 m2 (110%)
WATER FLOW RATE :
12300 kg/sec
COOLING WATER TEMPERATURE (In/Out):
 
28 / 35.72 C
PRESSURE (Shell):
0.5 barg / vacuum
TUBES (Material / Size):
SS 316L , 19.05 mmOD
 
 
FEED WATER PUMPS
 
QUANTITY :
6 (3x50% for each unit)
 
 
TYPE :
Multi stage horizontal centrifugal barrel type
RATING (Flow / TDH):
680 m3/hr / 2180 mwg
SUPPLIER :
In Bidding Phase
 
 
CIRCULATING WATER PUMPS
 
QUANTITY :
4 (2x50% for each unit)
TYPE :
Vertical centrifugal wet pit type
RATING :
22680 m3/hr / 20.75 mwg
SUPPLIER :
Termomeccanica Pompe
 
 
COMPRESSED AIR SYSTEM
 
MAIN COMPRESSOR :
4 (Water cooled)
CAPACITY :
1700 SCMH each
SUPPLIER :
In Bidding Phase
EMERGENCY COMPRESSOR :
1 (Air cooled) w/capacity of 850 SCMH
DRYERS :
2 w/capacity of 2375 SCMH each
RECEIVERS :
2 w/capacity of 8 m3

Print