STEAM GENERATOR |
|
|
MANUFACTURER: |
CMI |
|
QUANTITY : |
2 |
|
TYPE : |
Vertical |
|
MCR FLOW : |
HP: 167.98 (kg/sec)
IP: 181.72 (kg/sec) |
|
100% FLOW : |
|
|
SUPERHEATER OUTLET : |
HP: 149.32 (Kg/sec) at 130.23 (bar) |
|
REHEATER OUTLET : |
IP: 174.68 (Kg/sec) at 23.33 (bar) |
|
FUEL : |
Natural Gas (Solar as backup) |
|
|
|
|
MAIN TURBINE |
|
|
MANUFACTURER : |
Alstom |
|
QUANTITY : |
One (3 pressure HP, IP & LP turbine) |
|
TYPE : |
Model (HD2MD3ND41) [Reaction Type] |
|
THROTTLE CONDITIONS : |
HP:
· P 125.43 (bar)
· T 565.6 (0C)
· M 149.32 (kg/sec)
IP :
· P 22.03 (bar)
· T 565.5(0C)
· M149.32 (kg/sec)
LP:
· P 4.735(bar)
· T341.2(0C)
· M 193.25 (kg/sec) |
|
|
|
|
MAIN GENERATOR |
|
|
QUANTITY : |
1 - Model (50WX23Z-109) |
|
RATING : |
272 MW at 0.85 lagging |
|
TYPE OF COOLING : |
TEWAC (Totally Enclosed Water To Air Cooling) |
|
|
|
|
CONDENSER |
|
|
QUANTITY : |
1 |
|
RATING : |
439.67 (MW) |
|
EFFECTIVE COOLING SURFACE : |
Data is not available |
|
WATER FLOW RATE : |
13.2 m3/sec |
|
COOLING WATER TEMPERATURE : |
27 |
|
PRESSURE : |
0.074 (bar) |
|
TUBES : |
316L |
|
|
|
|
FEED WATER PUMPS |
|
|
QUANTITY : |
Total 6 pumps:
· 3x50% HP, IP feed water pumps
· 3x50% LP feed water pumps |
|
|
|
|
TYPE : |
Data is not available |
|
RATING : |
HP/IP: 98 (kg/sec) at 150 (m)
LP: 10.45 (Kg/sec) at 10.45 (m) |
|
SUPPLIER : |
Data is not available |
|
|
|
|
CIRCULATING WATER PUMPS |
|
|
QUANTITY : |
3 |
|
TYPE : |
Vertical |
|
RATING : |
6.6 m3/sec and 19.1 m head |
|
SUPPLIER : |
Data is not available |
|
|
|
|
COMPRESSED AIR SYSTEM |
|
|
MAIN COMPRESSOR : |
Total 4 compressors:
· 2x100 % instrument compressors
· 2x100 % service compressors |
|
CAPACITY : |
955 (m3/hr) per each |
|
SUPPLIER : |
Boge |
|
EMERGENCY COMPRESSOR : |
NA |
|
DRYERS : |
800 (m3/hr) per each (Supplier: Boge) |
|
RECEIVERS : |
5 m3 per each (total 3 receivers) |