El-Kureimat III Combined Cycle Power Plant (750 MW) Main Technical Parameters Minimize

 

STEAM GENERATOR
 
MANUFACTURER:
CMI
QUANTITY :
2
TYPE :
Vertical
MCR FLOW :
HP: 167.98 (kg/sec)
IP: 181.72 (kg/sec)
100% FLOW :
 
SUPERHEATER OUTLET :
HP: 149.32 (Kg/sec) at 130.23 (bar)
REHEATER OUTLET :
IP: 174.68 (Kg/sec) at 23.33 (bar)
FUEL :
Natural Gas (Solar as backup)
 
 
MAIN TURBINE
 
MANUFACTURER :
Alstom
QUANTITY :
One (3 pressure HP, IP & LP turbine)
TYPE :
Model (HD2MD3ND41) [Reaction Type]
THROTTLE CONDITIONS :
HP:
·          P 125.43 (bar)
·          T 565.6 (0C)
·          M 149.32 (kg/sec)
IP :
·          P 22.03 (bar)
·          T 565.5(0C)
·          M149.32 (kg/sec)
LP:
·          P 4.735(bar)
·          T341.2(0C)
·          M 193.25 (kg/sec)
 
 
MAIN GENERATOR
 
QUANTITY :
1 - Model (50WX23Z-109)
RATING :
272 MW at 0.85 lagging
TYPE OF COOLING :
TEWAC (Totally Enclosed Water To Air Cooling)
 
 
CONDENSER
 
QUANTITY :
1
RATING :
439.67 (MW)
EFFECTIVE COOLING SURFACE :
Data is not available
WATER FLOW RATE :
13.2 m3/sec
COOLING WATER TEMPERATURE :
27
PRESSURE :
0.074 (bar)
TUBES :
316L
 
 
FEED WATER PUMPS
 
QUANTITY :
Total 6 pumps:
·          3x50% HP, IP feed water pumps
·          3x50% LP feed water pumps
 
 
TYPE :
Data is not available
RATING :
HP/IP: 98 (kg/sec) at 150 (m)
LP: 10.45 (Kg/sec) at 10.45 (m)
SUPPLIER :
Data is not available
 
 
CIRCULATING WATER PUMPS
 
QUANTITY :
3
TYPE :
Vertical
RATING :
6.6 m3/sec and 19.1 m head
SUPPLIER :
Data is not available
 
 
COMPRESSED AIR SYSTEM
 
MAIN COMPRESSOR :
Total 4 compressors:
·          2x100 % instrument compressors
·          2x100 % service compressors
CAPACITY :
955 (m3/hr) per each
SUPPLIER :
Boge
EMERGENCY COMPRESSOR :
NA
DRYERS :
800 (m3/hr) per each (Supplier: Boge)
RECEIVERS :
5 m3 per each (total 3 receivers)

Print