Cairo West Thermal Power Plant (2x350 MW) Main Technical Parameters Minimize

STEAM GENERATOR
 
MANUFACTURER:
Not awarded yet
QUANTITY :
2
TYPE :
Drum type gas/oil fired
MCR FLOW :
304
100% FLOW :
289.6
SUPERHEATER OUTLET :
182.1 bara/541°C
REHEATER OUTLET :
38.6 bara/541°C
FUEL :
N.G/Mazout
 
 
MAIN TURBINE
 
MANUFACTURER :
MHI
QUANTITY :
2
TYPE :
Condensing
THROTTLE CONDITIONS :
166.5 bara/538°C
 
 
MAIN GENERATOR
 
QUANTITY :
2
RATING :
350MW
TYPE OF COOLING :
Hydrogen cooled
 
 
CONDENSER
 
QUANTITY :
2
RATING :
1429.1*106kJ/hr
EFFECTIVE COOLING SURFACE :
23100 m2
WATER FLOW RATE :
10320kg/s
COOLING WATER TEMPERATURE :
25°C
PRESSURE :
0.067 bara
TUBES :
22.23mm OD
 
 
FEED WATER PUMPS
 
QUANTITY :
6
 
 
TYPE :
Barrel type
RATING :
Q = 695m3/hr, H = 2270m
SUPPLIER :
Not awarded yet
 
 
CIRCULATING WATER PUMPS
 
QUANTITY :
4
TYPE :
Vertical Wet Pit
RATING :
Q = 5.34m3/s , H = 12.6m
SUPPLIER :
Not awarded yet
 
 
COMPRESSED AIR SYSTEM
 
MAIN COMPRESSOR :
 
CAPACITY :
4 x 1700 Nm3/hr
SUPPLIER :
Not awarded yet
EMERGENCY COMPRESSOR :
1 x 850 Nm3/hr
DRYERS :
2 Skids
RECEIVERS :
2 x 9m3

 
 
Print