COMPRESSOR TURBINE |
|
MANUFACTURER : General Electric. |
|
QUANTITY : Two (2). |
|
MODEL : 9351FA. |
|
TYPE : Heavy Duty. |
|
SPEED : 3000 rpm |
|
MAXIMUM RATING : 256.1 MW |
|
FUEL : Primary: Natural Gas Secondary: No. 2 oil |
|
|
|
COMPRESSOR |
|
NUMBER OF STAGES : 301.3 MVA (max) 15.75 KV 50 Hz. |
|
0.85 power factor lag to 0.9 power factor lead |
|
FREQUENCY : 50 Hz |
|
TYPE OF COOLING : Hydrogen cooled. |
|
EXCITATION : Static. |
|
|
|
COMBINED CYCLE |
|
HRSG |
|
MANUFACTURER: NEM |
|
QUANTITY : Two (2) |
|
TYPE : Horizontal / Tipple pressures with reheat |
|
MCR FLOW : 611 Ton/ Hr {HP : 269 HRH: 314 LP:27 } |
|
SUPERHEATER OUTLET : 568.90C & 129.2Bar |
|
REHEATER OUTLET : 560.9 C& 23.29 Bar |
|
|
|
STEAM TURBINE |
|
MANUFACTURER : Alstom Power Generation |
|
QUANTITY : one (1) |
|
POWER : 263.4 MW |
|
TYPE : Indoor single reheat condensing steam. |
|
THROTTLE PRESSURE : 122.68 bars. |
|
THROTTLE TEMPERATURE : 565.840 C |
|
|
|
GENERATOR |
|
RATING : 342 MVA / 18 KV |
|
0.85 power factor lag- 0.9 power factor lead. |
|
TYPE OF COOLING : Hydrogen. |
|
|
|
CONDENSER |
|
QUANTITY : One (1) |
|
EFFECTIVE COOLING SURFACE : 18.1040 m2 |
|
COOLING WATER FLOW : 45.000 m3 /hr |
|
COOLING WATER TEMPERATURE : 270 C |
|
PRESSURE : 52.2 mm HgA |
|
TUBES : 316L |
|
|
|
CIRCULATING WATER PUMPS |
|
QUANTITY : Two (2) |
|
TYPE : Vertical. |
|
RATING : 24.500 M3 /hr & 14.3 M TDH |
|
SUPPLIER : Flowserve. |
|
|
|
PROCUREMENT PACKAGES : 5 Packages |