Login     Sunday, September 07, 2008
El Atf Combined Cycle Power Plant (750 MW) Main Technical Parameters Minimize

STEAM GENERATOR [HRSG]
 
MANUFACTURER:
*
QUANTITY :
2
TYPE :
Heat Recovery Steam Generator
MCR FLOW [Kg/s]:
79.18*
100% FLOW [Kg/s] :
74.66*
SUPERHEATER OUTLET [bara]:
130.23*
REHEATER OUTLET [bara]:
26.72*
FUEL :
No supplementary firing
 
 
MAIN TURBINE
 
MANUFACTURER :
Ansaldo or ALstom*
QUANTITY :
1
TYPE :
Condensate steam turbine
THROTTLE CONDITIONS [Kg/s / bar / oC] :
149.32 / 125.43 / 565.62
 
 
MAIN GENERATOR
 
QUANTITY :
1
RATING :
*
TYPE OF COOLING :
*
 
 
CONDENSER
 
QUANTITY :
1
RATING [Kj/hr] :
1,523,383,936 *
EFFECTIVE COOLING SURFACE [m2]:
17,273.66*
WATER FLOW RATE [Kg/s] :
12,981.0*
COOLING WATER TEMPERATURE oC:
28*
PRESSURE [bar a]:
0.0718*
TUBES :
*
 
 
FEED WATER PUMPS
 
HP/IP pump
 
QUANTITY :
3 x 50%
TYPE :
ring-section, horizontal, centrifugal, vertical split-case*
RATING [Kg/s / bara] :
74.66 / 143.85
SUPPLIER :
*
 
 
LP pump
 
QUANTITY :
3 x 50%
TYPE :
ring-section, horizontal, centrifugal, vertical split-case*
RATING [Kg/s / bara] :
7.56 / 6.24*
SUPPLIER :
*
 
 
CIRCULATING WATER PUMPS
 
QUANTITY :
3 x 50%
TYPE :
vertical, open suction, wet pit type, single stage, mixed flow, centrifugal pump
RATING [ m3/s / 15.3 m ] :
6.5 / 15.3*
SUPPLIER :
*
 
 
COMPRESSED AIR SYSTEM
 
MAIN COMPRESSOR :
*
CAPACITY :
*
SUPPLIER :
*
EMERGENCY COMPRESSOR :
*
DRYERS :
*
RECEIVERS :
*
 
 
MANUFACTURER:
MHI
QUANTITY :
2
Model :
M701 F
Net power MW
266.5
Net heat rate [KJ/Kwh]
9,642
Exh. Energy LHV[[GJ/hr]
1574
 
 

 Notes:
* In formation under tendering process.
 